HIGH VACUUM DEGASSIFIER CMM-4,0 
 

Oil degassing, drying and filtration mode - 4000 l/h

Oil heating and filtration mode - 6000 l/h 


 

 
Dehydration, degassing and filtration of oil

Drying of transformer with simultaneous treatment of the oil

First filling of electrical apparatuses with insulating oil 



APPLICATION

High vacuum systems serve for degassing, dehydration and filtration of transformer oils for removal of gases, free and soluble water and particulate matter. The system is applied while installation, repair and operating of oil-filled high voltage equipment up to 1150 kV (power transformers, high-voltage switches etc.).

Contamination of electrical transformers with solids, liquids and gases during manufacture and operation is unavoidable. Costs of disposal or changing of insulating oils are frequently very high and need a significant investment. Our equipment offers a practical, proven and economical method to purify the oil and use it again for high voltage equipment.

Thermally accelerated Vacuum Dehydration and Degassing of Transformer Oil has gained wide acceptance as the most economical method for the removal of dissolved water and gases. On-Site Transformer Oil Purification is the most profitable as not only does it purify the oil within the transformer, but it actively regenerates the Transformer by removing impurities which build up within the transformer.


 
As option can be mounted on roadworthy trailer


TECHNICAL PARAMETERS

Name of parameter 

Value 

 1  Capacity, l/h

 

- in degassing, dehydration and filtration mode

4000

- in heating and filtration mode

6000

 2  Maximum oil temperature when heating and filtration, C0

90 

 3  Maximum oil temperature when drying and degassing, C0 65

 4  Outlet pressure, bar

3

 5  Head of oil delivery related to outlet ofthe plant, m 35

 6  Oil heater capacity, kW

50

 7  Vacuum valuein vacuum chamber when degassing, mbar 1
 8  Set power consumption, kW 58
 9*Supply voltage, 3 phase, AC, 50 Hz, V  400

 10 Dimensions, mm





- length

1650

- width

1250

- height

1600

 Weight, kg
 1000
*Power supply parameter as per clients’ requirement



GUARANTEED OIL PARAMETERS ACHIEVED WITH THE PLANT AFTER 1 PASS

Oil parameter

Unit

Test method

Before treatment

After treatment

Dissolved Gas Content

%

ASTM D-2945-71

≥ 12%

≤ 0,1%

Water Content

ppm

ASTM D-1744-64

≥ 100

≤ 5

Dielectric Strength

kV

IEC 60156

≤ 20 kV

≥ 60 kV

 


MAIN COMPONENT PARTS

 
 

1 - vacuum column 2 - oil input pump 3 - oil output pump 4 - pipeline system   5 - oil heater  6 - fine filter 7 - pre-evacuation vacuum pump 8 - vacuum booster (Roots type)



MODES OF OPERATION

 

The unit can be operated in the following modes:

 

- oil pumping

- oil heating and filtration

- oil degassing and dehydration

- transformer evacuation


 

Download PDF (Adobe Reader required)